ACTCAD Software Updates & Fixes

If you'd like to learn more about ACTCAD software or meet our team in person, feel free to visit one of our offices. ACTCAD has a global presence in various countries.

The new versions are available to download from the ACTCAD Download Page.

ActCAD 2021 version 1001464 released for below products:

  • ActCAD 2021 BIM
  • ActCAD 2021 Professional
  • ActCAD 2021 Standard

This is a general maintenance with few improvements and bug fixes. Below is a detailed log of changes:

  • Fixed issues with annotative dimension text scaled on every edit
  • Fixed the sysvars RECOMPUTEDIMBLOCKSREQUIRED & RECOMPUTEDRAWING
  • Fixed Publish command for selected sheet details do not match in output
  • Fixed the issue of layers filter applied wrong in the dropdown
  • Fixed some issues with Licensing
  • Fixed the slow loading issue of CUIX files
  • Fixed the issues of splash images not chaning
  • Fixed the issues of line types and profiles
  • Fixed the crash issue of colorbooks dialog
  • Fixed the command line focus issue of Dynamic screen input
  • Fixed the German language keyboard issue of letter N
  • Fixed some CUI file customization issues
  • Fixed the crash issue of Color dialog when called from IRX
  • Fixed text duplication when using \n at the beginning of a line
  • Fixed hanging issue of ActCAD when Editor.WriteMessage method called from .Net applications
  • Fixed the issue of Hatch using select entities in a particular drawing
  • Fixed exception issue of Hatch boundary in a particular drawing with select entities option
  • Fixed the hatch creation issue of Circles
  • Fixed Mleader text height changing issue
  • Fixed the issue of MLEADER does not display correct text height
  • Fixed the issue of Rotated multiline text positioned wrong
  • Fixed selection options from the drop-down list using the cursor and the Enter button
  • Fixed Transient graphics not displayed if raster image is frozen
  • Revised ODA libraries version to 6235
  • Fixed Arc negative angle value works wrong
  • Fixed 3X lines creation performance degradation

The new version is available for download from our downloads page.

ActCAD 2021 version 1001447 released for below products:

  • ActCAD 2021 BIM
  • ActCAD 2021 Professional
  • ActCAD 2021 Standard

This is a general maintenance with few improvements and bug fixes. Below is a detailed log of changes:

  • Fixed the PDF open and edit issue
  • Added a new setup file ActCAD PDF Printer
  • Introduced new Geo Location Feature and support for KMZ files
  • Fixed some issues to User Interface
  • Revision of ODA libraries to version 6214
  • Fixed 3X Lines creation performance degradation
  • Fixed SDS callback with SDS_CBXFORMSS flag
  • Fixed crash on snap to OdDgShape2d
  • Fixed crash issue of view manager dialog
  • Fixed crash issue of certain Dimstyle record associated with xrefs
  • Fixed old MTEXT editor does not apply color
  • Fixed exception in case of xref file is missing
  • Fixed exception in case of xref file name has unhandled characters
  • Fixed viewports that require 3d rendering issue
  • Added check and fix of viewports that require 3d rendering
  • Fixed PEDIT tangent option behaves wrong

The new version is available for download from our downloads page.

ActCAD 2021 version 1001439 released for below products:

  • ActCAD 2021 BIM
  • ActCAD 2021 Professional
  • ActCAD 2021 Standard

This is a major release with several improvements and fixes. Below is a detailed log of improvements:

  • Software updated to latest IntelliCAD 10.0a engine
  • Choose the color of print stamps
  • Provision for print stamps to print upside down
  • New Commands: Show Palettes and Hide Palettes
  • Multi-line text features superscript, subscript and strikethrough character formatting
  • New paragraph formatting options
  • On-the-fly spell checking option
  • Performance improvements in editing and selecting entities, text, and blocks

The new version is available for download from our downloads page.

ActCAD announces the release of its new version 2021. Below are the new products available:

  • ActCAD 2021 BIM
  • ActCAD 2021 Professional
  • ActCAD 2021 Standard

Below are the highlights of in this new Version:

  • Support for 2021 dwg & dxf files
  • Dynamic Screen Input
  • IntelliCAD 10 Engine & ODA 20.12 Libraries
  • New material library for Objects and Layers
  • New Visual styles
  • Import OBJ & STL Files
  • All new Geometric Technology
  • OpenGL ES Graphics Technology
  • 2D & 3D Anti-aliasing
  • All new Start Page with Create & Learn Tabs
  • Support for Table Formulae
  • New Spot and Point Lights in 3D
  • ActCAD 2021 supports Gradient Colors and Image Backgrounds
  • Several improvements to Printing and Plotting
  • Several improvements to User Interface and Icons
  • New BIM features: Roofs, Beams, Mitered Joints, explode BIM underlays
  • Several improvements to Features and Performance
  • Improved PDF to CAD Conversion Technology
  • Improved MText formatting, 4K Display, closed entities to Solids etc.
  • Introduced BIM PROPERTIES & BIM UNITS Commands
  • SYSVAR IMPORT & EXPORT and Improved sysvar dialogue
  • Introduce MIGRATEUI to import
  • customized user interface
  • Improved HOLETABLE command
  • Selection Grips for solid models
  • Tool Palettes Navigate for quick access

The new version is available for download from our downloads page.

ActCAD 2020 new version 92764 released for below products:

  • ActCAD 2020 BIM - 64bit
  • ActCAD 2020 Professional - 64bit
  • ActCAD 2020 Professional - 32bit
  • ActCAD 2020 Standard - 64bit
  • ActCAD 2020 Standard - 32bit

This is a minor maintenance release with few fixes. Please read below:

  • Complete improvements to Polish language interface
  • Revision of ODA libraries to version 6128
  • Fixed the issue of Revit underlay scaled after reopen
  • Fixed the issue of Print with Transparency giving wrong result (preview and print)

The new version is available for download from our downloads page.

ActCAD 2020 new version 92760 released for below products:

  • ActCAD 2020 BIM - 64bit
  • ActCAD 2020 Professional - 64bit
  • ActCAD 2020 Professional - 32bit
  • ActCAD 2020 Standard - 64bit
  • ActCAD 2020 Standard - 32bit

This is a minor maintenance release with few fixes. Please read below:

  • Fixed the resolution issue of ActCAD PDF Printer. Removed the default 2400 dpi resolution. Now user can set desired resolution while printing PDF files from ActCAD
  • Implemented CHT language translation completely
  • Fixed page setup name issue in Publish command

The new version is available for download from our downloads page.

ActCAD 2020 new version 92759 released for below products:

  • ActCAD 2020 BIM - 64bit
  • ActCAD 2020 Professional - 64bit
  • ActCAD 2020 Professional - 32bit
  • ActCAD 2020 Standard - 64bit
  • ActCAD 2020 Standard - 32bit

This is a major maintenance release with some improvements and bug fixes:

  • Added new command ATTEDIT
  • Added new command TOTALLENGTH
  • Added new command TOTALAREA
  • Added new command CENTERLINE
  • Added new commands TABLE_LOCK, TABLE_UNLOCK, TABLE_REFRESH, HELPVIDEOS, TUTORIALS etc.
  • Added new commands HELPDEVIRX, HELPDEVDOTNET and added them to User Interface
  • Added new menu for snap button in status bar
  • Modified several icons on User Interface
  • Fixed some issues in Numbered Markers program
  • Fixed the issue of Tangent Snaps from entities
  • Fixed some issues with Block Library
  • Fixed some issues with Table Editing
  • Fixed the text height issue of Table cell text
  • Fixed the access rights issues of Video Tutorials
  • Fixed certain crash while updating Leader
  • Fixed the issue of BHATCH slow island detection
  • Fixed certain crash with Hatch vertex deletion
  • Fixed crash with some click on Ribbon panel
  • Fixed the issue of LISP functions not repeated by pressing Enter button
  • Fixed some issues with copy in zoom out
  • Fixed print progress dialog does not contain layout information to track current plotting document
  • Fixed save button should be enabled after removing unsaved drawing from the list
  • Improved the detailed error information when BIMATTACH fails

The new version is available for download from our downloads page.

ActCAD 2020 new version 92735 released for below products:

  • ActCAD 2020 BIM - 64bit
  • ActCAD 2020 Professional - 64bit
  • ActCAD 2020 Professional - 32bit
  • ActCAD 2020 Standard - 64bit
  • ActCAD 2020 Standard - 32bit

This is a minor maintenance release with some fixes:

  • Modified several icons on user interface
  • Added link to User Guide in user interface
  • Fixed blurry icons on Toolbars
  • Fixed PDF2DXF command execution
  • Fixed issues of USEVIEWTWIST sysvar while modifying DIMTOH and DIMTIH
  • Fixed some issues with BIMATTACH
  • Fixed the issue of .NET IExtensionApplication
  • Fixed icad.net autoload method
  • Fixed Document manager reactors
  • Fixed some crash issues of IFC underlays

The new version is available for download from our downloads page.

ActCAD 2020 new version 92735 released for below products:

  • ActCAD 2020 BIM - 64bit
  • ActCAD 2020 Professional - 64bit
  • ActCAD 2020 Professional - 32bit
  • ActCAD 2020 Standard - 64bit
  • ActCAD 2020 Standard - 32bit

This is a major release with several new features and improvements. Please find the list of detailed improvements below:

  • All new TABLE creation command showing row and column headings, new dynamic effects etc.
  • All new TABLEEDIT command for direct on-screen editing 
  • All new Enhanced Block Attributes Editor
  • Introduced new TABLE STYLE command 
  • Introduced new BATTMAN command
  • Introduced new PATHARRAY command
  • Fixed some issues in QDIM command
  • Fixed some issues in Numbered Markers command
  • Fixed several issues on User Interface and enabled 11 color themes
  • Fixed hang issue with raster printing
  • Fixed PDF Export command to make the entities, with bylayer color, visible
  • Fixed hanging issue while using mouse buttons during FM3DCONVERT command
  • Fixed some issues with PDF import
  • Fixed some crash with Viewports
  • Fixed MTEXT issues like font name growth, SHX font does not change with style in properties pane, incorrect font display etc.
  • Fixed Chamfer issue, nor working in some cases
  • Fixed Chamfer issue when applied on polylines
  • Fixed crash issue while getting points on 3D curve
  • Fixed some hanging issues in Image Dialog
  • Fixed creation of thumbnail from selection set in .net API
  • Fixed the wrong messages in Selection Filter
  • Fixed empty tables in dialog boxes for Steel, Sjt, wood
  • Fixed ENTPROP issue of not showing some properties for multiple MTEXT objects
  • Fixed certain crash issue while getting entity info
  • Fixed the issues of taskbar thumbnails
  • Fixed certain crash issues while getting object context databaseReactorManager
  • Fixed some crash issues while adding selection reactor
  • Fixed hang issue while zooming large drawings
  • Fixed display problem of entities after selection cycling
  • Fixed the failure notification issue in Publish command
  • Fixed the crash issue during find and replace text in a block
  • Fixed incorrect Units format in page setup manager
  • Fixed paper size value retaining issue in print dialog
  • Fixed the Autocomplete window display in BIM module
  • Fixed the jig effect issues in door & wall commands
  • Updated latest ODA 4.3 libraries

The new version is available for download from our downloads page. We recommend existing users to reinstall the software as there are major changes.

ActCAD 2020 new version 92711 released for below products:

  • ActCAD 2020 BIM - 64bit
  • ActCAD 2020 Professional - 64bit
  • ActCAD 2020 Professional - 32bit
  • ActCAD 2020 Standard - 64bit
  • ActCAD 2020 Standard - 32bit

This is a general maintenance release with few minor improvements. Below are the changes in this version:

  1. All new Network Licensing Technology to support multiple products from ActCAD.
  2. Added "-units" command
  3. Added over 660 Color Books for ActCAD entities
  4. Improved User Interface and some icons for better visibility
  5. Improved MTEXT toolbar icons and colors

The new version is available for download from our downloads page.

ActCAD announces the release of new version 92710 for below mentioned products:

  • ActCAD 2020 Standard - 64bit
  • ActCAD 2020 Standard - 32bit
  • ActCAD 2020 Professional - 64bit
  • ActCAD 2020 Professional - 32bit
  • ActCAD 2020 BIM - 64bit

Here is a detailed list of improvements and bug fixes:

  1. Added new command QDIM
  2. Added new command SAVEAS options
  3. Added new command ImportCSVText
  4. Added new DXF export with some options
  5. Fixed some issues in Hole Table command
  6. Fixed some issues in Export Table command
  7. Fixed some issues in Numbered Markers command
  8. Fixed some issues in Export Text Labels command
  9. Added right mouse click options for DIMTEXT commands
  10. Introduced Video tutorials module launch using WEBVIDEOS command
  11. Several Improvements to User Interface and Colors
  12. Fixed the double click issue of CMDACTIVE
  13. Fixed the support issue of TTF font
  14. Fixed the issue of USEVIEWTWIST works incorrectly in UCS
  15. Fixed the issues of MTEXT & MLEADER
  16. Fixed the MENULOAD issue
  17. Fixed Freeze/Thaw Layers in viewport performance issue
  18. Fixed crash on viewport activate in OpenGL
  19. Fixed the issue of view snapshot update
  20. Fixed the issue of DGN file closing issue when DWG is opened
  21. Fixed teh issues of workspace sysvars
  22. Fixed MTEXT default wrong height
  23. Fixed cursor state inconsistency after zoom while drop down is shown
  24. Fixed the issue of Object becomes invalid after erase during OnDocumentCreated event
  25. Added new condition for view snapshot update
  26. Fixed wrong annotation scale value in properties panel on the Layout tab displays
  27. Fixed wrong text height of annotative text entities in viewports
  28. Fixed MTEXT position shift in text editor
  29. Fixed the crash issue when printing a particular drawing
  30. Fixed some regression test scripts
  31. Fixed crash issue while switching between documents when CUI dialog is running
  32. Fixed -DVIEW Camera option activates a dialog and allow command line input
  33. Fixed some -viewctl command behavior
  34. Fixed rework MASSPROP command to fix mass properties calculation for multiple regions and solids
  35. Fixed RESETUI affecting some other sysvars
  36. Fixed setting current workspace from CUI dialog doesn't update workspace sysvars
  37. Fixed profile update from current workspace on save if a workspace object was changed
  38. Fixed the issue of USEVIEWTWIST works incorrectly in UCS
  39. Fixed some issues related to null selection set
  40. Fixed some crash issue on CDwgRealTime method
  41. Fixed crash of Old MTEXT exception on MTEXT edit
  42. Fixed zoom stops working after Undo in some cases
  43. Fixed the issue of SaveAs 2004 and layer names change
  44. Fixed ENTPROP wrong behavior with simple entities
  45. Fixed some crash issues related to viewport border change
  46. Fixed wome wrong behavior of WBLOCK

New versions are available for download from our Downloads page. Feel free to contact us if you need more information.

ActCAD announces the release of new version 92690 for below-mentioned products:

  • ActCAD 2020 BIM - 64bit
  • ActCAD 2020 Professional - 64bit
  • ActCAD 2020 Professional - 32bit
  • ActCAD 2020 Standard - 64bit
  • ActCAD 2020 Standard - 32bit

Below are the important changes in this particular release:

  1. Added new command to Create HOLETABLE
  2. Added new command for NumberedMarkers
  3. Added new command to Export Table Data to CSV file
  4. Added new command to Export Text Labels from drawing to CSV file
  5. Updated to latest patch of IntelliCAD Engine to 9.2a engine or ODA libraries
  6. Fixed some issues related to ribbon docking
  7. Fixed certain issues related to Layer Freeze/Thaw
  8. Fixed the issue of wrong file type in SAVEAS dialog
  9. Fixed the startup freese issue with AMD Ryzen Threadripper 2990WX 32 core
  10. Fixed GetVectorTo value issue in VB.NET API
  11. Fixed crash issues related to cursor graphics
  12. Fixed certain issues related to Geo Data variables
  13. fixed the subroutine issue of Actor
  14. Fixed selection cycling glyph to turn off
  15. Fixed BIM some license issues related to BIM

The new versions are available for download from our downloads section. Existing users can use the "Check For Updates" command to automatically update the latest patch.